## [Unreleased]

- Accept a stable near-zero residual for zero targets after 10 seconds within +/-0.5 bar and a 0.01 bar stability band; display ZERO STABLE while retaining the measured pressure.

- Add independent Stop buttons for long term measurements, keeping the last result visible until a new measurement starts.
- Display available short term averaging history out of five minutes and long term history from 0 / 120 min.

Expand Down
6 changes: 6 additions & 0 deletions cross_platform/docs/PACE_Controller_Manual.md
Original file line number Diff line number Diff line change
Expand Up @@ -253,6 +253,12 @@ Rows execute from top to bottom. Dwell begins only after the PACE reports in-lim

At completion the software requests MEASURE unless **Keep CONTROL after final step** was explicitly selected. Timeouts and user interruption request MEASURE.

### Stable residual at target zero

When the requested target is exactly 0 bar, the application also accepts a near-zero plateau even if the instrument never reports IN LIMIT. The residual must remain within +/-0.5 bar and the pressure range over 10 seconds must not exceed 0.01 bar, with continuous valid readings. A pressure still decreasing or a plateau outside this tolerance does not qualify.

The target card shows **ZERO STABLE** (Italian: **ZERO STABILE**). The measured residual remains displayed and logged at its actual value; it is not replaced by zero and the instrument's IN LIMIT flag is not altered. Manual, indenting and routine zero steps can complete, or start their requested dwell, using this condition. Starting another step, leaving CONTROL, missing telemetry or disconnecting clears the stability history. Nonzero targets retain the instrument's normal IN LIMIT criterion.

## 12. Software protection rules

### 12.1 Large target change
Expand Down
2 changes: 2 additions & 0 deletions cross_platform/src/pace_controller/i18n.py
Original file line number Diff line number Diff line change
Expand Up @@ -39,6 +39,7 @@
"valve_effort": "Valve effort",
"state": "State",
"target_state": "Target",
"zero_target_stable": "ZERO STABLE",
"source_margin": "Source margin",
"manual": "1 MANUAL",
"indenting": "2 INDENTING",
Expand Down Expand Up @@ -182,6 +183,7 @@
"valve_effort": "Sforzo valvole",
"state": "Stato",
"target_state": "Target",
"zero_target_stable": "ZERO STABILE",
"source_margin": "Margine sorgente",
"manual": "1 MANUALE",
"indenting": "2 INDENTING",
Expand Down
1 change: 1 addition & 0 deletions cross_platform/src/pace_controller/models.py
Original file line number Diff line number Diff line change
Expand Up @@ -70,6 +70,7 @@ class Telemetry:
valve_effort_percent: float = nan
control: bool = False
in_limits: bool = False
zero_target_stable: bool = False
source_margin_bar: float = nan


Expand Down
26 changes: 25 additions & 1 deletion cross_platform/src/pace_controller/service.py
Original file line number Diff line number Diff line change
Expand Up @@ -25,6 +25,7 @@
configure_dedicated_adapter,
restore_dedicated_adapter,
)
from .stability import ZeroTargetStability
from .storage import DataLogger
from .transports import ScpiTransport, TransportError, create_transport

Expand Down Expand Up @@ -96,6 +97,8 @@ def __init__(
self._poll_failures = 0
self._supply_interlock_latched = False
self._automation: dict[str, Any] | None = None
self._zero_target_monitor = ZeroTargetStability(maximum_gap_seconds=max(3.0, poll_interval * 3.0))
self._zero_target_reported = False

@property
def telemetry(self) -> Telemetry:
Expand Down Expand Up @@ -253,6 +256,9 @@ def _connect(self, config: ConnectionConfig, module: int) -> None:
self.busy_changed.emit(False)

def _close_device(self, request_measure: bool, emit: bool = True) -> None:
self._zero_target_monitor.reset()
self._telemetry.zero_target_stable = False
self._zero_target_reported = False
self._cancel_automation()
if request_measure and self._connected:
try:
Expand Down Expand Up @@ -386,6 +392,9 @@ def _start_current_step(self) -> None:
def _apply_pressure_step(
self, step: PressureStep, parameters: ControlParameters
) -> None:
self._zero_target_monitor.reset()
self._telemetry.zero_target_stable = False
self._zero_target_reported = False
module = self._module
self._write("*CLS")
self._write(f":UNIT{module}:PRES BAR")
Expand Down Expand Up @@ -417,7 +426,7 @@ def _process_automation(self, now: float) -> None:
index = int(self._automation["index"])
step = steps[index]
if state == "waiting":
if self._telemetry.in_limits:
if self._telemetry.in_limits or (step.target_bar == 0.0 and self._telemetry.zero_target_stable):
if step.dwell_seconds > 0:
self._automation["state"] = "dwelling"
self._automation["dwell_end"] = now + step.dwell_seconds
Expand Down Expand Up @@ -477,6 +486,9 @@ def _start_vent(self, parameters: ControlParameters) -> None:
self._write_log(f"VENT started at {parameters.vent_rate_bar_s} bar/s.")

def _set_measure(self) -> None:
self._zero_target_monitor.reset()
self._telemetry.zero_target_stable = False
self._zero_target_reported = False
self._require_connected()
self._write(f":OUTP{self._module}:STAT OFF")
self._assert_no_error()
Expand Down Expand Up @@ -511,11 +523,23 @@ def _poll(self) -> None:
in_limits=in_limits,
source_margin_bar=margin,
)
self._telemetry.zero_target_stable = self._zero_target_monitor.add(
time.monotonic(), current, target, control
)
if self._telemetry.zero_target_stable and not in_limits:
if not self._zero_target_reported:
self._write_log(f"Zero target accepted at stable residual pressure {current:.6f} bar (within +/-0.5 bar, stable for 10 s).")
self._zero_target_reported = True
else:
self._zero_target_reported = False
self._poll_failures = 0
self.telemetry_received.emit(self._telemetry)
self.logger.telemetry(self._telemetry)
self._check_source_interlock()
except Exception as exc:
self._zero_target_monitor.reset()
self._zero_target_reported = False
self._telemetry.zero_target_stable = False
self._poll_failures += 1
was_control = self._telemetry.control
self._write_log(f"Telemetry failure {self._poll_failures}: {exc}")
Expand Down
41 changes: 41 additions & 0 deletions cross_platform/src/pace_controller/stability.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,41 @@
"""Recognition of a stable residual when a zero target is not attainable."""

from collections import deque
from math import isfinite


class ZeroTargetStability:
"""Accept a near-zero plateau, never a stalled pressure outside the tolerance."""

def __init__(self, maximum_gap_seconds: float = 3.0) -> None:
self.tolerance_bar = 0.5
self.duration_seconds = 10.0
self.band_bar = 0.01
self.maximum_gap_seconds = maximum_gap_seconds
self.samples: deque[tuple[float, float]] = deque()

def reset(self) -> None:
self.samples.clear()

def add(self, timestamp: float, pressure_bar: float, target_bar: float, control: bool) -> bool:
if (
not control
or target_bar != 0.0
or not isfinite(timestamp)
or not isfinite(pressure_bar)
or abs(pressure_bar) > self.tolerance_bar + 1e-9
):
self.reset()
return False
if self.samples:
gap = timestamp - self.samples[-1][0]
if gap <= 0 or gap > self.maximum_gap_seconds:
self.reset()
self.samples.append((timestamp, pressure_bar))
cutoff = timestamp - self.duration_seconds
# Retain the point spanning the beginning of the observation interval.
while len(self.samples) > 1 and self.samples[1][0] <= cutoff:
self.samples.popleft()
elapsed = timestamp - self.samples[0][0]
pressures = [value for _, value in self.samples]
return elapsed >= self.duration_seconds and max(pressures) - min(pressures) <= self.band_bar + 1e-9
6 changes: 4 additions & 2 deletions cross_platform/src/pace_controller/ui.py
Original file line number Diff line number Diff line change
Expand Up @@ -1113,9 +1113,11 @@ def on_telemetry(self, telemetry: object) -> None:
self.metrics["state"].value.setStyleSheet(
"color: #b42318;" if telemetry.control else "color: #2459e0;"
)
self.metrics["target_state"].value.setText("IN LIMIT" if telemetry.in_limits else "MOVING")
self.metrics["target_state"].value.setText(
"IN LIMIT" if telemetry.in_limits else self.t("zero_target_stable") if telemetry.zero_target_stable else "MOVING"
)
self.metrics["target_state"].value.setStyleSheet(
"color: #078419;" if telemetry.in_limits else "color: #d56a00;"
"color: #078419;" if telemetry.in_limits or telemetry.zero_target_stable else "color: #d56a00;"
)
self.metrics["source_margin"].value.setText(self.format_metric(telemetry.source_margin_bar, "bar"))
self.metrics["source_margin"].value.setStyleSheet(
Expand Down
81 changes: 81 additions & 0 deletions cross_platform/tests/test_zero_target.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,81 @@
import pytest

from pace_controller.models import ControlParameters, PressureStep, Telemetry
from pace_controller.service import PaceService
from pace_controller.stability import ZeroTargetStability


def test_zero_accepts_stable_residual_only_after_ten_seconds():
monitor = ZeroTargetStability()
for timestamp in range(10):
assert not monitor.add(timestamp, 0.5, 0.0, True)
assert monitor.add(10.0, 0.5, 0.0, True)
assert not monitor.add(11.0, 0.48, 0.0, True)


@pytest.mark.parametrize("pressure,target,control", [
(0.51, 0.0, True), (5.0, 0.0, True),
(0.5, 0.1, True), (0.5, 0.0, False), (float("nan"), 0.0, True),
])
def test_zero_rejects_outside_tolerance_nonzero_target_and_invalid_readings(pressure, target, control):
monitor = ZeroTargetStability()
for timestamp in range(15):
assert not monitor.add(timestamp, pressure, target, control)


def test_zero_does_not_accept_a_slow_ramp_or_missing_telemetry():
monitor = ZeroTargetStability()
for timestamp in range(20):
assert not monitor.add(timestamp, 0.49 - timestamp * 0.002, 0.0, True)
monitor.reset()
for timestamp in range(11):
stable = monitor.add(timestamp, 0.49 + (0.002 if timestamp % 2 else 0.0), 0.0, True)
assert stable
assert not monitor.add(20.0, 0.49, 0.0, True)
assert not monitor.add(21.0, 0.49, 0.0, True)


@pytest.mark.parametrize("target,stable,dwell,expected", [
(0.0, True, 0.0, "complete"),
(0.0, True, 5.0, "dwelling"),
(0.0, False, 0.0, "waiting"),
(1.0, True, 0.0, "waiting"),
])
def test_automation_accepts_zero_plateau_without_hardware_in_limit(monkeypatch, tmp_path, target, stable, dwell, expected):
monkeypatch.setenv("PACE_CONTROLLER_DATA_DIR", str(tmp_path))
service = PaceService()
service._telemetry = Telemetry(current_pressure_bar=0.5, target_pressure_bar=target, control=True, in_limits=False, zero_target_stable=stable)
service._automation = {"steps": [PressureStep(target, 0.1, dwell)], "index": 0, "state": "waiting", "deadline": 100.0}
completed = []
service._complete_step = lambda: completed.append(True)
service._process_automation(20.0)
if expected == "complete":
assert completed
else:
assert not completed
assert service._automation["state"] == expected


def test_poll_recognizes_zero_plateau_and_preserves_true_pressure(monkeypatch, tmp_path):
monkeypatch.setenv("PACE_CONTROLLER_DATA_DIR", str(tmp_path))
service = PaceService()
service._connected = True
clock = [0.0]
monkeypatch.setattr("pace_controller.service.time.monotonic", lambda: clock[0])
values = {
":SENS1:PRES:CONT?": "0.5", ":SOUR1:PRES?": "0",
":OUTP1:STAT?": "1", ":SOUR1:PRES:COMP1?": "50",
":SENS1:PRES:INL?": "0",
}
service._query = lambda command: values.get(command, "0")
for timestamp in range(11):
clock[0] = float(timestamp)
service._poll()
assert service.telemetry.zero_target_stable
assert not service.telemetry.in_limits
assert service.telemetry.current_pressure_bar == 0.5
service._write = lambda command: None
service._assert_no_error = lambda: None
service._apply_pressure_step(PressureStep(0.0, 0.1), ControlParameters())
assert not service.telemetry.zero_target_stable
assert not service._zero_target_monitor.samples