Repository navigation
fix(labs): bộ chấm lab và HeadlessLab chỉ chọn AutoCAD 2021–2024 - #40
Merged
Merged
Conversation
run-lab.ps1 and run-headless-lab.ps1 picked the newest AutoCAD installed, so a machine with 2024 and 2025 chose 2025, which runs .NET 8 and cannot load the net48 DLLs built against the AutoCAD 2024 API. They now pick the newest install between 2021 and 2024 (-AcCorePath still overrides) and say why when none is found. labs/README said '2021 or later'; README §4 and tests/integration/README state the range. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Sửa lưu ý số 1 trước khi dùng tài liệu cho training.
Vấn đề
labs/run-lab.ps1vàtests/integration/run-headless-lab.ps1tự chọn bản AutoCAD mới nhất đã cài. Máy có cả AutoCAD 2024 lẫn 2025 thì chúng chọn 2025.labs/READMElại ghi "AutoCAD 2021 trở lên", tức sai với bản 2025+.Sửa
AutoCAD 20xxvà chỉ khi cóaccoreconsole.exe.-AcCorePathvẫn chọn tay được.labs/README, training/README §4 và README củatests/integrationghi rõ giới hạn 2021–2024.run-integration-tests.ps1giữ nguyên, vì nó có tham số riêng-TargetFramework net8.0-windowscho 2025+.Đã kiểm
accoreconsole.exe→ không chọn gì.run-lab.ps1 -Lab L06 -Solutionđạt 2/2,run-headless-lab.ps1đạt 22/22..ps1vẫn giữ BOM.npm run linksvàreading-time: 0 lỗi.🤖 Generated with Claude Code