At power-up the XBee queues a modem status frame, so ATTN is legitimately low when setup() samples it right after begin(). The "LOW (unexpected -- check module seating/wiring)" message fired on working hardware: the PAN ID and SL queries that follow succeed, and the AT command path already skips that queued frame. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Problem
On the new boards, every boot printed
XBee ATTN pin at boot: LOW (unexpected -- check module seating/wiring), even though the XBee worked: the PAN ID and SL queries right after it succeeded.The check assumed ATTN idles HIGH at boot. In API mode, though, the XBee queues a modem status frame when it powers up, and over SPI ATTN stays low while a frame is waiting. Sampling ATTN right after
xbeeControl.begin(), before anything reads that frame, sees LOW on working hardware.sendAtCommand()already skips that frame, so nothing else needs to change.Fix
Remove the diagnostic. A real wiring or seating problem still shows up as the existing
XBee PAN ID query failed/XBee SL query failedboot messages.pio runbuilds. No logic changed, so no new tests.🤖 Generated with Claude Code