Hybrid CNN–Quantum Neural Network for Breast Cancer Classification: an honest reproduction + profiling
This repository reproduces the method of the AIIoT 2025 paper "A Novel Hybrid CNN-Quantum Neural Network Framework with Quantum Acceleration and Error Correction for High-Precision Breast Cancer Classification on AI Edge Devices" on a public dataset, compares it with a classical baseline and a size-matched classical control, and profiles where training time and memory actually go — as groundwork for FPGA acceleration of hybrid CNN–QNN models.
TL;DR
- On CBIS-DDSM (mass ROI crops) the hybrid model reaches 70.8 ± 1.5 % test accuracy vs 72.7 ± 0.8 % for the classical ResNet152 (3 seeds, 378 held-out test images). Far from the ~97 % reported in the original paper.
- Replacing the 8-qubit circuit by a classical
Linear(8,8)+tanhlayer of the same size gives 70.0 ± 0.6 %. Hybrid vs. control: McNemar p = 0.74 / 0.22 / 0.59 over the three seeds. The circuit adds nothing measurable; the small drop vs. the classical model comes from the 2048 → 8 bottleneck. - In a hybrid training step the frozen ResNet152 forward takes ~94 % of the time; the simulated
8-qubit layer (forward + backward) takes 6 % with our GPU simulator (12 % with PennyLane on CPU;
NVIDIA's cuQuantum-based
lightning.gpuis 90× slower than our simulator at this size). - At 8 qubits the simulation is overhead-bound (~17 µs per gate on GPU, ~50 kFLOP of real work per sample); simulator memory grows as gates × 2ⁿ × batch and runs out on a 6 GB GPU at 18 qubits.
CBIS-DDSM from Kaggle,
Mass subset, cropped ROIs only. Put jpeg/ and csv/ into ./archive/.
| split | images | patients | malignant | benign |
|---|---|---|---|---|
| official train (→ 80/20 train/val, grouped by patient) | 1318 | 691 | 637 | 681 |
| official test (used once, at the end) | 378 | 201 | 147 | 231 |
Labels: 0 = MALIGNANT, 1 = BENIGN (incl. BENIGN_WITHOUT_CALLBACK). No patient appears in both
official splits.
| Benign (class 1) | Malignant (class 0) |
|---|---|
![]() |
![]() |
- Classical: ImageNet ResNet152,
layer3,layer4and head fine-tuned (AdamW, lr 1e-5 backbone / 1e-3 head), dropout 0.5 +Linear(2048, 2). - Hybrid ("dressed" quantum head, quantum transfer learning): the classical model's fine-tuned
backbone is frozen; head =
Linear(2048,8) → tanh·π/2 → 8-qubit circuit → Linear(8,2). Circuit: H on all qubits, RY angle encoding, 6 × [CNOT ladder (even then odd pairs) + trainable RY], ⟨Z⟩ on every qubit. 16,458 trainable parameters. - Control: identical to the hybrid but the circuit is replaced by
Linear(8,8) + tanh(bounded like ⟨Z⟩). 16,482 trainable parameters. This isolates what the circuit itself contributes.
Shared: same augmentation as the original scripts, class-balanced sampling, 60 epochs, ReduceLROnPlateau, best checkpoint = lowest val loss, evaluated once on the official test set. Seeds 42/43/44; the hybrid and control of seed s use the backbone of classical seed s.
--middle |
what | device |
|---|---|---|
torch (default) |
our batched state-vector simulator in plain PyTorch, real float32 amplitudes (H, RY, CNOT are real), autograd | GPU or CPU |
pennylane |
the original PennyLane default.qubit TorchLayer, pinned to CPU |
CPU |
pennylane-gpu |
default.qubit on CUDA, made to work by starting from a `StatePrep( |
0…0⟩)` that lives on the GPU |
lightning |
PennyLane lightning.qubit (adjoint gradients) |
CPU |
lightning-gpu |
PennyLane lightning.gpu / NVIDIA cuStateVec (adjoint; pip install pennylane-lightning-gpu) |
GPU |
classical |
the ablation control above | — |
python quantum.py checks that the torch simulator matches PennyLane (forward and gradients agree to
~1e-7). Checkpoints are interchangeable between quantum backends.
Note: with PennyLane 0.45, a default.qubit TorchLayer moved to CUDA crashes (its initial state is created
on the CPU), so the original qnn.py cannot run its quantum layer on the GPU as written.
| Model | Test acc % | Balanced acc % | AUC (malignant) | Recall malignant % | Recall benign % | Trainable params |
|---|---|---|---|---|---|---|
| Classical ResNet152 | 72.7 ± 0.8 | 71.8 ± 1.1 | 0.780 ± 0.012 | 68.0 ± 2.7 | 75.6 ± 0.9 | 55.6 M |
| Hybrid (8-qubit QNN head) | 70.8 ± 1.5 | 70.2 ± 1.5 | 0.768 ± 0.005 | 67.3 ± 3.0 | 73.0 ± 2.5 | 16,458 |
| Control (Linear(8,8)+tanh head) | 70.0 ± 0.6 | 70.4 ± 1.0 | 0.780 ± 0.014 | 72.1 ± 4.5 | 68.7 ± 2.9 | 16,482 |
Paired tests on the 378 test images (same seed): see results/compare/stats.txt.
None of the 9 comparisons survives a Bonferroni correction (p < 0.0056).
What this does not support (corrections to the earlier version of this README):
- "Quantum sensitivity to malignant cases." The earlier single run showed 73 % vs 67 % malignant recall. Over 3 seeds the hybrid's malignant recall (67.3 %) is no higher than the classical model's (68.0 %), and the classical control is highest (72.1 %): this is an operating-point effect of the small head, not a quantum one.
- "Accelerated convergence." The hybrid head peaks at epoch 2–12, but so does the classical control (epoch 2–8): any small head on an already fine-tuned backbone converges fast.
The original scripts split train/val by row. With the same seed, 181 of 264 val images (69 %) had their
patient in the training set, and 160 lesions had their other mammographic view (CC/MLO) in training —
hence val accuracy (76.5 %) overstated test accuracy (71.7 %). The new split is grouped by patient_id.
- Hybrid step: frozen ResNet152 forward 108 ms (bf16) vs quantum head fwd+bwd 6.7 ms (our GPU sim), 5.8 ms (our sim, CPU), 14.1 ms (PennyLane CPU), 19.8 ms (PennyLane GPU). Accelerating only the quantum layer can speed up a training step by at most ~6 % (Amdahl).
- Classical fine-tuning step: 124 ms fwd + 129 ms bwd, 2.3 GB peak with bf16 autocast; 237 + 258 ms, 4.4 GB in fp32.
- Scaling: at ≤ 8 qubits time grows with the number of gates, not with 2ⁿ (kernel-launch/framework overhead); the GPU overtakes the CPU from ~10 qubits (16 qubits: 115 ms vs 505 ms forward). Backprop simulation stores a state per gate: 937 MB at 16 qubits, OOM at 18 on 6 GB.
- PennyLane Lightning (adjoint gradients):
lightning.qubit(CPU) 58.7 ms andlightning.gpu(NVIDIA cuStateVec) 600 ms per batch-32 fwd+bwd at 8 qubits, vs 6.7 ms for our GPU simulator. Lightning devices do not broadcast over the batch, so each of the 32 samples is a separate circuit execution (~19 ms fixed cost each onlightning.gpu); they target single large circuits, not small batched ones.lightning.gpuis still 22× slower at 14 qubits (2.0 s vs 91 ms).
| quantum head, 8 qubits, batch 32 | fwd + bwd (ms) |
|---|---|
| our simulator, CPU | 5.8 |
| our simulator, GPU | 6.7 |
PennyLane default.qubit, CPU |
14.1 |
PennyLane default.qubit, GPU |
19.9 |
PennyLane lightning.qubit, CPU |
58.7 |
PennyLane lightning.gpu (cuQuantum) |
600 |
Raw numbers: results/profile_3050/*.csv and results/profile_3050_lightning/*.csv (lightning only:
python profile_hybrid.py --backends lightning-cpu,lightning-gpu --out results/profile_3050_lightning),
environment in env.txt.
source ~/qnn-env/bin/activate # Python 3.12; torch, torchvision, pennylane, pandas, scikit-learn, matplotlib, scipy
python build_index.py # archive/ -> data/{train,test}_index.csv
python quantum.py # simulator correctness check vs PennyLane
nohup ./run_all.sh > runs/run_all.log 2>&1 & # 3 seeds x {classical, hybrid, control}, ~55 min on an RTX 3050
python compare.py # -> results/compare/
python profile_hybrid.py --out results/profile_3050 # run with the GPU otherwise idleSingle runs:
python train.py --model classical --out runs/classical_s42
python train.py --model hybrid --backbone runs/classical_s42/best.pth --out runs/hybrid_s42
python train.py --model hybrid --middle classical --backbone runs/classical_s42/best.pth --out runs/hctrl_s42Useful flags: --batch 16 (if CUDA OOM), --epochs, --patience, --seed, --no-amp, --limit N (debug).
| file | purpose |
|---|---|
build_index.py |
CBIS-DDSM CSVs → image index with patient ids |
common.py |
dataset, patient-grouped split, ClassicalResNet, DressedHead, HybridModel |
quantum.py |
GPU state-vector simulator + PennyLane backends |
train.py |
training + one-shot test evaluation for all models |
run_all.sh, post_train.sh |
full experiment; comparison + profiling after it |
compare.py |
tables, McNemar / bootstrap statistics, figures |
profile_hybrid.py |
forward/backward time + memory profiling |
results/ |
comparison and profiling outputs |
runs/ |
per-run logs, result.json, test predictions (checkpoints are gitignored) |
legacy/ |
the original scripts, logs and figures (row-split validation) |
poster/ |
LaTeX source of the poster |
- One dataset (CBIS-DDSM masses), one backbone, three seeds; differences of 1–2 points are ~4–8 test images.
- The quantum layer is simulated (noise-free state vector); no quantum hardware is used. The original paper's "quantum acceleration" and "error correction" are not reproduced.
- The hybrid and control heads sit on a backbone already fine-tuned by the classical model, so they compare heads on identical features.