calc[244] and calc[252] are configuration setpoints (max supply / max hot-gas temp), not sensors #269

Open

Description

@Rouzax

On firmware V3.90.4 (WZSV 92K3M, brine/water inverter), two still-Unknown_Calculation indices are easily mis-decoded as sensors — they are actually static configuration setpoints, verified against the web UI (Instellingen → Temperaturen):

index meaning scaling web-UI label example
244 max supply (flow) temperature setpoint raw ÷ 10 → °C "Aanvoer max." 660 → 66.0 °C
252 max hot-gas (discharge) cut-off setpoint raw ÷ 10 → °C "T-HG max." 1150 → 115.0 °C

252 especially: it is a constant 115 °C setpoint — not a condensing pressure or live sensor, which the value/scaling can be mistaken for.

These are firmware-extended calculations (present on recent firmware, ≥~3.88); meanings may differ on other firmware generations.

Decoded while working on a Domoticz plugin for these pumps: https://github.com/Rouzax/luxtronik-domoticz-plugin-v2

Activity

  1. Guzz-T commented on Jul 1, 2026

    @Guzz-T
    Contributor

    For calculation 252, also note #180 and #262

  2. Guzz-T commented on Jul 1, 2026

    @Guzz-T
    Contributor

    ToDo @Rouzax:

    Then @Guzz-T :

    • Swap the order of the entries for each index
    • Add the current field as successor for the new field