calc[244] and calc[252] are configuration setpoints (max supply / max hot-gas temp), not sensors #269
On firmware V3.90.4 (WZSV 92K3M, brine/water inverter), two still-Unknown_Calculation indices are easily mis-decoded as sensors — they are actually static configuration setpoints, verified against the web UI (Instellingen → Temperaturen):
index
meaning
scaling
web-UI label
example
244
max supply (flow) temperature setpoint
raw ÷ 10 → °C
"Aanvoer max."
660 → 66.0 °C
252
max hot-gas (discharge) cut-off setpoint
raw ÷ 10 → °C
"T-HG max."
1150 → 115.0 °C
252 especially: it is a constant 115 °C setpoint — not a condensing pressure or live sensor, which the value/scaling can be mistaken for.
These are firmware-extended calculations (present on recent firmware, ≥~3.88); meanings may differ on other firmware generations.
Activity
Guzz-T commentedon Jul 1, 2026
For calculation 252, also note #180 and #262
Guzz-T commentedon Jul 1, 2026
ToDo @Rouzax:
Then @Guzz-T :